Nobel Biocare® Compatible

Cementing Instructions for Titanium Inserts:

Prior to bonding, make sure the screws fall through the hole of the zirconia restoration. If there is a problem you will need to manually enlarge the hole.

  1. Sandblast the exterior of the Ti inserts (DO NOT SAND BLAST THE INTERFACING PART OF THE ABUTMENT) and the receiving area of the zirconia with aluminum oxide.
  2. Screw the abutments to the model.
  3. Blackout top of screw with some white wax.
  4. Apply the primer to the brush and apply a liberal coat to the insert and Zi receiving area. Allow to day for a minute and then fully dry with air.
  5. Syringe a couple of beads of the resin cement circumferentially around the titanium insert.
  6. Light cure the screw access hole, buccal and lingual for 3 seconds, each location.
  7. Using an explorer remove excess resin
  8. Finish light curing all units.
  9. Examine under microscope for excess cement.

Download the Complete Catalog

Download the Usage Instructions

 


Sort by
Display per page

NT-Trading E-Series 2-CONnect Nobel Replace Select® Compatible Base Set

Multi-Unit Implant Systems The new 2-CONnect system from NT-Trading is specifically designed for fabricating hybrid multi-unit restorations like screw-retained bridges and implant bars. The system enables connecting implants with up to 35 degree divergence. It uses all digital manufacturing and is incredibly accurate.

NT-Trading E-Series Nobel Replace Select® Compatible Titanium Bases

The NT-Trading E and F Series products, intended for custom milled zirconia abutments, are made of Grade 5 titanium and include abutment screw.

Scan Bodies and 3D Guides are constructed from the advanced biomaterial PEEK and ready for scanning while the lab analog’s are made from high strength stainless steel.

NT-Trading E-Series Nobel Replace Slelect® Compatible 3-D Guides

The NT-Trading E and F Series products, intended for custom milled zirconia abutments, are made of Grade 5 titanium and include abutment screw.

Scan Bodies and 3D Guides are constructed from the advanced biomaterial PEEK and ready for scanning while the lab analog’s are made from high strength stainless steel.

NT-Trading E-Series Screws Nobel Replace Slelect® Compatible Screws

The NT-Trading E and F Series products, intended for custom milled zirconia abutments, are made of Grade 5 titanium and include abutment screw.